A heat pipe heat recovery heat exchanger for a mini-drier

Authors

  • A Meyer Department of Mechanical Engineering, University of Stellenbosch, Stellenbosch
  • R T R T Dobson Department of Mechanical Engineering, University of Stellenbosch, Stellenbosch

DOI:

https://doi.org/10.17159/2413-3051/2006/v17i1a3364

Keywords:

Heat pipe heat exchangers, thermosyphons, air drying, energy savings

Abstract

This paper considers the thermal design and the experimental testing of a heat pipe (thermosyphon) heat exchanger for a relatively small commercially available mini-drier. The purpose of the heat exchanger is to recover heat from the moist waste air stream to preheat the fresh incoming air. The working fluid used was R134a and the correlations are given for the evaporator and condenser inside heat transfer coefficients as well as for the maximum heat transfer rate. The theoretical model and computer simulation program used for the thermal design calculations are described. The validity of the as-designed and manufactured heat exchanger coupled to the drier is experimentally verified. The theoretical model accurately predicted the thermal performance and a significant energy savings and a reasonable payback period was achieved.

Downloads

Download data is not yet available.

References

Dunn DP and Reay D, 1994, Heat pipes, 4th Edition,

Pergamon.

Incropera FP and DeWitt DP, 2002, Fundamentals of

Heat and Mass Transfer, Wiley.

Meyer A, 2004, Development of a Range of Air-to-Air

Heat Pipe Heat Recovery Heat

Exchangers, MSc Thesis, University of Stellenbosch,

Stellenbosch.

Meyer A and Dobson RT, 2005, Thermal performance characterization of R134a and Butane charged twophase

closed thermosyphons, R & D Journal (submitted

for review and publication).

Mills AF, 1995, Heat and Mass Transfer, Richard D. Irwin.

Pioro LS and Pioro IL, 1997, Industrial Two-phase

Thermosyphons, Begell House.

Russwurm AE, January 1980, Q-pipes add a new dimension

to waste heat recovery, recycling energy – Part 1,

Heating, Air Conditioning & Refrigeration (Now

Refrigeration and Air Conditioning), pp 27-39.

Russwurm AE, March 1980, Recovering waste heat with

Q-pipes, recycling energy – Part 2 – Recycling energy,

Heating, Air Conditioning & Refrigeration (Now

Refrigeration and Air Conditioning), pp 45-49.

Downloads

Published

2006-02-01

How to Cite

Meyer, A., & R T Dobson, R. T. (2006). A heat pipe heat recovery heat exchanger for a mini-drier. Journal of Energy in Southern Africa, 17(1), 50–57. https://doi.org/10.17159/2413-3051/2006/v17i1a3364